Electrical power is transmitted over long distances through overhead transmission and distribution lines. Such overhead lines are designed based on voltage, power to be tranmitted, environmental conditions, hindrances along the right of way, crossings, soil conditions, ease of availability of equipment and accessories and few other commercial criteria. Sag & Tension calculations for a overhead line is one calculation which determines the span and strength of towers / poles carrying the live conductors. We use PLS CADD software for these calculations. This category includes the following products :
Transmission Line Tower Structure Design
Get Best Quote
Approx. Price: Rs 1,200 / TonneGet Latest Price
Product Details:
Minimum Order Quantity
1 Tonne
Type Of Construction
Industrial
Industry
Transmission Line
Site Location
World wide
Material
GS
Material Procurement
By supplier
Mode Of Service
Design and drawings
Service Mode
Submission by email
Footings Type
Project based requirement
Number Of Floor
NA
Earthquake-Resistant
Yes
Is It Customised
Customisation
Brand
Satcon
Services Charge
Refer quotation
Feature
33kV to 400kV
Finishing
GS
Payment Mode
Bank to Bank
Features :
Our structural engineers have prior experience of performing design calculations and fabrication drawings of lattice structure for transmission line towers for 33kV and 400kV. The calculation is done by Staad software and drawings are prepared using Cad software latest version. A thorough analysis is done for the structures on the basis of the vertical, horizontal loads, conductor tension, wind loads, broken wire conditions etc. as per relevant National / International standards.
Request Callback
Additional Information:
Item Code: S-1
Production Capacity: 1 drawing and design per week
Transmission Line Tower Structure Design & Transmission Line Tower Foundation. Features :
Our structural engineers have prior experience of performing design calculations and fabrication drawings of lattice structure for transmission line towers for 33kV and 132kV. The calculation is done by Staad software and drawings are prepared using Autocad latest version. A thorough analysis is done for the structures on the basis of the vertical, horizontal loads, wind loads, broken wire conditions etc. as per relevant standards. We have senior experienced engineers who can design and prepare drawing for foundation of overhead transmission line towers upto 132kV voltage. The design is done on the basis of the loading data given by the tower supplier, wind load and soil bearing capacity.